Power Rider , 12 channels PDU

Power Rider , 12 channels PDU
Power Rider , 12 channels PDU

Power Rider , 12 channels PDU

​Overview

Highlights:

 

  • Up to 25A for each channel circuit breaker
  • 8- 48V DC
  • Circuit breaker (fuse), relay, and contactor in each channel
  • Tow levels of protection:
  • Software – I²t, over-current, over-voltage, over-temperature
  • Hardware – 1μ second over-current cutoff
  • Solid-state based technology
  • Configurable – over 20 flexible configuration parameters for each channel individually
  • Measurement of input voltage, output voltage, load current and temperature.
  • Communication:  CAN bus (50kbps-1Mbps - J1939), Ethernet (UDP) or RS 422/485.
  • Discrete I/O: 12 digital input, 2 digital output (open collector)
  • Option to connect up to two channels in parallel (up to 50 Ampere)
  • Sleep mode / Shut Down mode
  • BIT (Power-on and On-the-fly built-in test)
APPLY FOR MORE INFO
e90b1b_7e1dc4b5abd7482189ce53c7b2f05c16~mv2-1
Redler Technologies

CONTACT US

Channels PDU, Mil Std 12 Power Rider

Channels PDU, Mil Std 12 Power Rider
Channels PDU, Mil Std 12 Power Rider

Channels PDU, Mil Std 12 Power Rider

​Overview

    •  

      • Up to 25A for each channel circuit breaker
      • 8- 48V DC
      • Circuit breaker (fuse), relay, and contactor in each channel
      • Tow levels of protection:
      • Software – I²t, over-current, over-voltage, over-temperature
      • Hardware – 1μ second over-current cutoff
      • Solid-state based technology
      • Configurable – over 20 flexible configuration parameters for each channel individually
      • Measurement of input voltage, output voltage, load current and temperature.
      • Communication:  CAN bus (50kbps-1Mbps - J1939), Ethernet (UDP) or RS 422/485.
      • Discrete I/O: 12 digital input, 2 digital output (open collector)
      • Option to connect up to two channels in parallel (up to 50 Ampere)
      • Sleep mode / Shut Down mode
      • BIT (Power-on and On-the-fly built-in test)
APPLY FOR MORE INFO
e90b1b_7e1dc4b5abd7482189ce53c7b2f05c16~mv2-1
Redler Technologies

CONTACT US

Power Rider , 16 channels PDU, Mil Std

Power Rider , 16 channels PDU, Mil Std
Power Rider , 16 channels PDU, Mil Std

Power Rider , 16 channels PDU, Mil Std

​Overview

    • Up to 25A for each channel circuit breaker

    • 8- 48V DC 

    • Circuit breaker (fuse), relay, and contactor in each channel

    • Three levels of protection:

    • Software – I²t, over-current, over-voltage, over-temperature

    • Hardware – 1μ second over-current cutoff

    • Thermal fuse

    • Solid-state based technology

    • Cascade option

    • Circuit breaker support network

    • Configurable – over 20 flexible configuration parameters for each channel individually

    • Intuitive GUI, DLL library

    • Building block for ‘Power Distribution Unit’

    • Measurement of input voltage, output voltage, load current and temperature

    • Communication:  CAN bus (50kbps-1Mbps - J1939), Ethernet (UDP) or RS 422/485.

    • Advanced reporting and easy maintenance – event logs, graphs, conditional alerts

    • Discrete I/O: 12 digital input, 2 digital output (open collector)

    • Option to connect up to two channels in parallel (up to 50 Ampere)

    • Sleep mode / Shut Down mode

    • BIT (Power-on and On-the-fly built-in test)

    • Full Mil-STD (Available in authorized territories only)

APPLY FOR MORE INFO
e90b1b_7e1dc4b5abd7482189ce53c7b2f05c16~mv2-1
Redler Technologies

CONTACT US

Engineering cables

Engineering cables - Power Accessories
Engineering cables - Power Accessories

Engineering cables

​Overview

  • Command and communication engineering harnesses

APPLY FOR MORE INFO
e90b1b_7e1dc4b5abd7482189ce53c7b2f05c16~mv2-1
Redler Technologies

CONTACT US